
Fit the additive measurement-error model (signal + measurement variance)
Source:R/fit_additive_weight.R
fit_additive_weight.RdFits a Bayesian Gaussian model in which each observation's variance is the
sum of true between-subject variance and measurement variance,
$$\sigma_i^2 = \tau^2 + \kappa^2\, se_i^{2\beta_1},$$
with a censored likelihood for samples outside the quantifiable range. It is
the default estimator of fit_precision_weights() from curveRweights 0.3.0.
Usage
fit_additive_weight(
df,
cell_col = "cell",
concentration_col = "predicted_concentration",
se_col = "se_concentration",
plate_col = "plate",
patient_col = NULL,
sample_col = NULL,
censor_col = NULL,
lower_col = "censor_lower",
upper_col = "censor_upper",
se_bound_col = NULL,
dilution_col = NULL,
response_is_log10 = FALSE,
fix_beta1 = TRUE,
fix_kappa = FALSE,
prior_location = brms::set_prior("normal(0, 2)", class = "b"),
prior_ltau = brms::set_prior("normal(-1.2, 1)", class = "b", nlpar = "ltau"),
prior_lkappa = brms::set_prior("normal(0, 0.5)", class = "b", nlpar = "lkappa"),
prior_beta1 = brms::set_prior("normal(1, 0.25)", class = "b", nlpar = "beta1"),
prior_group_sd = brms::set_prior("normal(0, 0.5)", class = "sd"),
iter = 2000,
warmup = 1000,
chains = 4,
cores = 4,
adapt_delta = 0.95,
seed = 42,
backend = NULL,
n_draws_weights = 1000
)Arguments
- df
Data frame with observation-level data.
- cell_col
Name of the saturated cell factor column.
- concentration_col
Predicted concentration column.
- se_col
Measurement SE column (log10 scale; the curveR
se_concentration).- plate_col
Plate (or curve) grouping column;
NULLfor none.- patient_col
Subject grouping column;
NULLfor none. Strongly recommended when subjects are measured more than once.- sample_col
Optional column identifying a physical sample measured several times (dilutions/replicates). Not recommended yet: the sample intercept absorbs the real between-sample variation, so tau describes only the scatter between readings of one sample and tends to zero (the ceiling on the weights is lost and sampling is poor). See NEWS (0.3.1).
- censor_col
Name of the censoring-type column (
"none","left","right","interval").NULL(default) treats every row as quantified.- lower_col, upper_col
Natural-scale censoring bounds.
- se_bound_col
Optional measurement SE at the censoring limit; see
prepare_censoring().- dilution_col
Optional dilution-factor column. If supplied, the response is converted to the final-concentration scale (
yi + log10(dilution)), which is the scale curveRcore's censoring bounds are on. Supply it whenever you use curveRcore censoring bounds and dilutions differ.- response_is_log10
Is
concentration_colalready log10?- fix_beta1
Fix \(\beta_1 = 1\) (default) or estimate it.
- fix_kappa
Fix \(\kappa = 1\) instead of estimating it (default
FALSE). WithTRUEthe calibration curve'sseis taken as the true measurement SD and only \(\tau\) is estimated. Use it when \(\kappa\) is weakly identified (thesevalues barely differ between samples), or when you trust the curve'sse. Theidentifiabilitynote then says that \(\kappa\) was fixed.- prior_location, prior_ltau, prior_lkappa, prior_beta1, prior_group_sd
brms::priorobjects.- iter, warmup, chains, cores, adapt_delta, seed
MCMC controls.
- backend
Passed to
brms::brm();NULLuses the brms default.- n_draws_weights
Number of posterior draws used for the reliability interval (thinned from the fit).
Value
A list with fit, tau, tau2, kappa,
beta1, their credible intervals (tau_CI, kappa_CI,
beta1_CI), overall reliability and reliability_CI
(\(\tau^2/(\tau^2 + \bar v)\) over quantified rows), data (the full
input with the weight columns of compute_additive_weights()),
diagnostics (both models report the same convergence and
model-check entries: rhat_max, n_divergent, ess_min
(lowest bulk or tail ESS), ident_sd_ratio (posterior SD / prior SD
of the key scale parameter), resid_sd and resid_sd_ratio
(robust SD of the scaled residuals overall, and lowest-se fifth / highest-se
fifth), with kappa_sd_ratio the same as ident_sd_ratio),
formula and priors_used.
In plain terms
An assay value varies between subjects for two different reasons. Subjects
truly differ (biology; this is the signal, variance \(\tau^2\)), and the
calibration curve measures each sample with some error (variance
\(v_i\), known to us through se_i). The two add. The older
multiplicative model of curveRweights 0.2.x instead made the whole
spread proportional to se, which implies that a precisely measured
sample has little biological variation, so it could be given a weight many
times larger than its neighbours. In the additive model the weight is at most
\(1/\tau^2\); no sample can count for more than a perfectly measured one.
\(\kappa\) is a calibration factor: \(\kappa = 1\) means the reported
se is exactly the measurement SD (the delta-method value). \(\beta_1\)
is fixed at 1 by default; \(\kappa\) and \(\tau\) are separated only
through the spread of se across samples, so freeing \(\beta_1\) as
well makes the model much harder to identify. Use fix_beta1 = FALSE
only with plenty of data over a wide range of se.
Model
Location: yi ~ 0 + cell + (1|patient) + (1|plate) [+ (1|sample)], where
cell is the saturated design factor (e.g. arm by time point). The
patient term absorbs correlation between repeated samples of the same
subject (otherwise counted as noise). The optional sample term is meant for
several dilutions or replicates of one physical sample, but see
sample_col: it is not recommended yet.
Scale: \(\sigma_i = \sqrt{\tau^2 + \kappa^2 se_i^{2\beta_1}}\) via a
non-linear sigma formula. Rows with censor_type left,
right or interval contribute a cumulative-probability term at
their censoring limit (see prepare_censoring()); quantified rows contribute
a normal density.
Default priors: location normal(0, 2); \(\log\tau \sim
N(\log 0.3, 1)\); \(\log\kappa \sim N(0, 0.5)\) (centred on the delta-method
value); \(\beta_1 \sim N(1, 0.25)\) when free; group SDs
normal(0, 0.5).