Analysing I-SPI exports: censoring, predictive intervals and precision
Source:vignettes/analysing-ispi-exports.Rmd
analysing-ispi-exports.RmdThis vignette is for analysts working downstream of I-SPI (or of the curveR packages directly) with back-calculated test-sample concentrations. It explains what the per-sample uncertainty columns mean, why samples outside the quantifiable range should be treated as censored rather than as imprecise points, and how to fit regression models that use every sample correctly.
All executable code below runs on a simulated data set built in the vignette, with the same column names as an I-SPI export, so no database is needed.
1. What an export gives you
Each back-calculated sample (calib_samples, or
tidy_samples() on a curveR result after
classify_censoring_multiplate()) carries:
| Column(s) | Meaning |
|---|---|
final_concentration |
Point estimate, natural scale, dilution-corrected |
se_concentration |
SD of the log₁₀ concentration (delta method or posterior SD) |
pcov |
100 · ln(10) · se_concentration, capped at 150 —
symmetric and direction-blind |
censor_class, censor_type
|
quantified / lod_to_lloq /
below_lod / below_lloq /
above_uloq / saturated; type none
/ left / interval / right
|
censor_lower, censor_upper
|
Censoring bounds, natural scale, dilution-corrected; NA
= unbounded (a left-censored lower bound is 0) |
conc_q_lo, conc_q_med,
conc_q_hi
|
2.5 / 50 / 97.5 % predictive quantiles, natural scale |
p_below_lloq, p_above_uloq,
p_below_cutoff
|
Probabilities from the predictive distribution |
frac_draws_below_a,
frac_draws_above_d
|
Share of draws beyond the curve’s asymptotes |
From the precision-weights tab (calib_weights,
calib_weights_fit): sigma, w,
w_norm per sample and phi, beta1
per group.
Why pcov is not enough. A sample below
the LLOQ has a true concentration bounded between 0 and about the LLOQ;
a sample above the ULOQ has no upper bound. Both can show the same
pcov, because pcov is one symmetric number on
the log scale, where both sides are open-ended. On the natural
scale the low sample is tightly bounded and often answers threshold
questions with certainty; the high one is not. Censoring columns carry
exactly that information.
2. Choosing a scale and building analysis columns
Analyse y = log₁₀(concentration): assay error is
roughly multiplicative, se_concentration is already on this
scale, and censoring bounds transform cleanly (a natural-scale lower
bound of 0 becomes −∞, coded NA).
set.seed(2026)
n_pat <- 120
pat <- data.frame(patientid = sprintf("P%03d", seq_len(n_pat)),
arm = rep(c("placebo", "vaccine"), each = n_pat / 2),
u = rnorm(n_pat, 0, 0.3)) # patient random effect
d <- merge(pat, data.frame(timeperiod = c("day0", "day28")))
d$arm <- factor(d$arm); d$timeperiod <- factor(d$timeperiod)
# true geometric means (log10): placebo 0.6 -> 0.8; vaccine 0.6 -> 2.0
mu_true <- with(d, 0.6 + 0.2 * (timeperiod == "day28") +
1.2 * (arm == "vaccine" & timeperiod == "day28"))
y_true <- mu_true + d$u + rnorm(nrow(d), 0, 0.4)
# measurement SE (log10): U-shaped precision profile
se_fun <- function(y) 0.05 + 0.35 * plogis((0.5 - y) / 0.15) + 0.35 * plogis((y - 3.0) / 0.15)
y_obs <- y_true + rnorm(nrow(d), 0, se_fun(y_true))
LOD <- 0.2; LLOQ <- 0.5; ULOQ <- 3.0 # log10, dilution 1
d$final_concentration <- 10^y_obs
d$se_concentration <- se_fun(y_obs)
d$censor_class <- with(d, ifelse(y_obs < LOD, "below_lod",
ifelse(y_obs < LLOQ, "lod_to_lloq",
ifelse(y_obs > ULOQ, "above_uloq", "quantified"))))
d$censor_type <- c(below_lod = "left", lod_to_lloq = "interval",
above_uloq = "right", quantified = "none")[d$censor_class]
d$censor_lower <- with(d, ifelse(censor_class == "lod_to_lloq", 10^LOD,
ifelse(censor_class == "above_uloq", 10^ULOQ, NA)))
d$censor_upper <- with(d, ifelse(censor_class == "below_lod", 10^LOD,
ifelse(censor_class == "lod_to_lloq", 10^LLOQ, NA)))
cutoff <- 10 # e.g. a protective level
d$p_below_cutoff <- pnorm((log10(cutoff) - y_obs) / d$se_concentration) # stand-in
table(d$arm, d$timeperiod, d$censor_class)[, , c("below_lod", "lod_to_lloq", "quantified")]
#> , , = below_lod
#>
#>
#> day0 day28
#> placebo 9 5
#> vaccine 14 0
#>
#> , , = lod_to_lloq
#>
#>
#> day0 day28
#> placebo 9 6
#> vaccine 4 0
#>
#> , , = quantified
#>
#>
#> day0 day28
#> placebo 42 49
#> vaccine 42 59Build the log-scale analysis columns once, using the
survival “interval2” convention: y_lo == y_hi
for an exact value, NA for an unbounded side.
d$y <- log10(d$final_concentration)
d$y_lo <- ifelse(d$censor_type %in% c("interval", "right"), log10(d$censor_lower), NA)
d$y_hi <- ifelse(d$censor_type %in% c("left", "interval"), log10(d$censor_upper), NA)
d$y_lo[d$censor_type == "none"] <- d$y[d$censor_type == "none"]
d$y_hi[d$censor_type == "none"] <- d$y[d$censor_type == "none"]3. Options at a glance
| Approach | Use when | Avoid when |
|---|---|---|
| Substitution (LLOQ/2, LLOQ/√2) | Sensitivity analysis only | Primary analysis: biased, SEs too small |
| Complete case (drop out-of-range) | Never as primary | Out-of-range depends on the outcome — it always does |
| Precision weights on every row | In-range noise heterogeneity | Out-of-range rows: weights fall because values are low, so weighted means drift up |
| Censored Gaussian (Tobit) | Regression on log₁₀ concentration | Very heavy censoring with no plausible distribution |
| Survival-style nonparametric | CDFs, medians, group comparisons without normality | Covariate-rich models |
| Bayesian censored likelihood | Repeated measures, known measurement error, full uncertainty | A quick frequentist answer suffices |
| Threshold probabilities | “Below the protective level?” questions | Estimating mean levels |
The substitution and complete-case rows are worth seeing fail:
truth <- c(`(Intercept)` = 0.6, armvaccine = 0, timeperiodday28 = 0.2,
`armvaccine:timeperiodday28` = 1.2)
cc <- lm(y ~ arm * timeperiod, data = d[d$censor_type == "none", ])
sub <- d; low <- sub$censor_type %in% c("left", "interval")
sub$y[low] <- log10(10^LLOQ / sqrt(2))
sub$y[sub$censor_type == "right"] <- ULOQ
sb <- lm(y ~ arm * timeperiod, data = sub)
round(cbind(truth, complete_case = coef(cc), substitution = coef(sb)), 2)
#> truth complete_case substitution
#> (Intercept) 0.6 0.87 0.71
#> armvaccine 0.0 0.11 0.08
#> timeperiodday28 0.2 0.13 0.17
#> armvaccine:timeperiodday28 1.2 0.85 1.02Complete-case analysis keeps only the placebo samples that happened to read high, so it overstates the placebo level and understates the vaccine effect.
4. Censored Gaussian regression (Tobit)
With μᵢ = xᵢᵀβ and residual SD σ, each row contributes
- quantified: φ((yᵢ − μᵢ)/σ)/σ
- left-censored at U: Φ((U − μᵢ)/σ)
- interval [L, U]: Φ((U − μᵢ)/σ) − Φ((L − μᵢ)/σ)
- right-censored at L: 1 − Φ((L − μᵢ)/σ)
Coefficients describe the latent (uncensored) log₁₀ concentration;
10^β is a geometric-mean ratio.
library(survival)
tob <- survreg(Surv(y_lo, y_hi, type = "interval2") ~ arm * timeperiod,
data = d, dist = "gaussian", robust = TRUE, cluster = patientid)
round(cbind(truth, tobit = coef(tob)), 2)
#> truth tobit
#> (Intercept) 0.6 0.65
#> armvaccine 0.0 0.04
#> timeperiodday28 0.2 0.20
#> armvaccine:timeperiodday28 1.2 1.08
round(summary(tob)$table[, c("Value", "Std. Err")], 3) # robust (patient-clustered) SEs
#> Value Std. Err
#> (Intercept) 0.652 0.055
#> armvaccine 0.045 0.089
#> timeperiodday28 0.198 0.061
#> armvaccine:timeperiodday28 1.081 0.093
#> Log(scale) -0.745 0.058robust = TRUE, cluster = patientid gives sandwich
standard errors for repeated measures; survreg has no
random effects (use section 6 or censReg for a random
intercept). AER::tobit() is a thin wrapper for left/right
censoring.
5. Using the measurement error too — and why weighting by it can bias
Tobit assumes one residual SD for every row. I-SPI tells you each sample’s own measurement SE, so it is tempting to split the residual into between-subject spread τ and known measurement error sᵢ:
\[ y_i \sim \mathcal N\!\left(\mu_i,\; \sqrt{\tau^2 + s_i^2}\right). \]
For a quantified row, sᵢ is se_concentration and the
implied precision weight is 1/(τ² + sᵢ²). For a censored row,
se_concentration is not meaningful (it is huge or
NA precisely because the sample is out of range), so the
censored probability uses the SE at the censoring
bound, read from the curve’s precision profile
(calib_grid: se = pcov / (100 · ln 10) at the
LLOQ / ULOQ / LOD). This is the “weights for in-range samples, censoring
indicators for out-of-range samples” model.
Caution. In an immunoassay the measurement SE is a function of the true concentration (the U-shaped precision profile). Inverse-variance weighting then down-weights samples because their true value is low (or high), and the fitted means drift toward the well-measured middle of the curve. This is the same informative-weighting problem as down-weighting out-of-range samples, and it happens even when the SEs are known exactly. In 200 replicates of the simulation below (same design, fresh data each time):
| Estimate | Bias: Tobit | Bias: weighted (true SE) | Bias: latent-variable | RMSE: Tobit | RMSE: weighted | RMSE: latent |
|---|---|---|---|---|---|---|
| Intercept (truth 0.6) | +0.029 | +0.097 | +0.040 | 0.074 | 0.117 | 0.101 |
| Interaction (truth 1.2) | −0.011 | −0.079 | −0.025 | 0.104 | 0.125 | 0.155 |
The fix is to model the error SD as a function of the latent true concentration tᵢ rather than plugging in a per-row SE: yᵢ ~ N(tᵢ, s(tᵢ)), tᵢ ~ N(μᵢ, τ), integrating over tᵢ (the “latent-variable” column; code below). It removes most of the bias, but on these data it is less precise than plain Tobit. Recommendation: use the censored model of section 4 for group means and effects; reach for the latent-variable model only when measurement error is large relative to between-subject spread; avoid plugging per-sample SEs in as weights for location estimates.
The naive weighted model, on the demonstration data:
X <- model.matrix(~ arm * timeperiod, d)
type <- d$censor_type
s_row <- d$se_concentration
s_lo <- se_fun(d$y_lo); s_hi <- se_fun(d$y_hi) # in practice: from calib_grid
negll <- function(par) {
mu <- drop(X %*% par[seq_len(ncol(X))]); tau <- exp(par[ncol(X) + 1])
ll <- numeric(nrow(X))
q <- type == "none"
ll[q] <- dnorm(d$y[q], mu[q], sqrt(tau^2 + s_row[q]^2), log = TRUE)
l <- type == "left"
ll[l] <- pnorm(d$y_hi[l], mu[l], sqrt(tau^2 + s_hi[l]^2), log.p = TRUE)
r <- type == "right"
ll[r] <- pnorm(d$y_lo[r], mu[r], sqrt(tau^2 + s_lo[r]^2), lower.tail = FALSE, log.p = TRUE)
iv <- type == "interval"
sd_iv <- sqrt(tau^2 + s_hi[iv]^2)
ll[iv] <- log(pnorm(d$y_hi[iv], mu[iv], sd_iv) - pnorm(d$y_lo[iv], mu[iv], sd_iv))
-sum(ll)
}
start <- c(coef(cc), log(0.5))
het <- optim(start, negll, method = "BFGS", hessian = TRUE)
est <- het$par[seq_len(ncol(X))]; se <- sqrt(diag(solve(het$hessian)))[seq_len(ncol(X))]
round(cbind(truth, heteroscedastic = est, se = se), 3)
#> truth heteroscedastic se
#> (Intercept) 0.6 0.708 0.060
#> armvaccine 0.0 0.073 0.084
#> timeperiodday28 0.2 0.187 0.083
#> armvaccine:timeperiodday28 1.2 0.995 0.116
c(tau = exp(het$par[ncol(X) + 1]))
#> tau
#> 0.4209088The latent-variable version integrates over the true concentration
with Gauss–Hermite quadrature. se_fun() stands for the
precision profile, which in practice you interpolate from
calib_grid (log10_concentration,
se = pcov / (100 · ln 10)):
gh <- function(k) { # Gauss-Hermite nodes/weights
i <- seq_len(k - 1); J <- matrix(0, k, k)
J[cbind(i, i + 1)] <- J[cbind(i + 1, i)] <- sqrt(i / 2)
e <- eigen(J, symmetric = TRUE); list(x = e$values, w = sqrt(pi) * e$vectors[1, ]^2)
}
G <- gh(40)
lo <- ifelse(is.na(d$y_lo), -Inf, d$y_lo); hi <- ifelse(is.na(d$y_hi), Inf, d$y_hi)
q <- type == "none"
negll_latent <- function(par) {
m <- drop(X %*% par[seq_len(ncol(X))]); tau <- exp(par[ncol(X) + 1])
tt <- outer(m, sqrt(2) * tau * G$x, "+") # latent true values at the nodes
st <- se_fun(tt) # error SD depends on the TRUE value
f <- matrix(0, nrow(tt), ncol(tt))
f[q, ] <- dnorm(d$y[q], tt[q, , drop = FALSE], st[q, , drop = FALSE])
f[!q, ] <- pnorm((hi[!q] - tt[!q, , drop = FALSE]) / st[!q, , drop = FALSE]) -
pnorm((lo[!q] - tt[!q, , drop = FALSE]) / st[!q, , drop = FALSE])
-sum(log(pmax(drop(f %*% G$w) / sqrt(pi), 1e-300)))
}
start_lat <- if (has_survival) c(coef(tob), log(0.5)) else start
lat <- optim(start_lat, negll_latent, method = "BFGS",
control = list(maxit = 1000, reltol = 1e-12))
round(cbind(truth, latent = lat$par[seq_len(ncol(X))]), 3)
#> truth latent
#> (Intercept) 0.6 0.673
#> armvaccine 0.0 -0.075
#> timeperiodday28 0.2 0.142
#> armvaccine:timeperiodday28 1.2 1.245All of these standard errors ignore the patient clustering; add a patient random effect (section 6) or use a cluster bootstrap for repeated measures.
6. Bayesian censored likelihood
The censored likelihood inside a hierarchical model with a patient
random effect. The simplest version (sigma ~ 1) is a
random-effects Tobit and is the recommended default. Adding a scale
model on the measurement SE — the analogue of curveRweights’ σᵢ =
φ·sᵢ^β₁ — is shown commented out; given section 5 it should be used for
location estimates only with that caveat in mind (or replaced by a
latent-variable formulation written directly in Stan):
library(brms)
d$cens <- d$censor_type # none/left/interval/right
d$yb <- ifelse(d$cens == "left", d$y_hi, ifelse(d$cens == "right", d$y_lo, d$y))
d$yb[d$cens == "interval"] <- d$y_lo[d$cens == "interval"]
d$y2 <- ifelse(d$cens == "interval", d$y_hi, NA)
# scale predictor: own SE when quantified, SE at the bound when censored
d$s_scale <- ifelse(d$cens == "none", d$se_concentration,
ifelse(d$cens == "right", s_lo, s_hi))
fit <- brm(bf(yb | cens(cens, y2) ~ arm * timeperiod + (1 | patientid)),
# sigma ~ log(s_scale) # measurement-SE scale model: see section 5
data = d, family = gaussian(), chains = 4, cores = 4,
prior = c(prior(normal(0, 2), class = "b"),
prior(normal(0, 1), class = "sd")))
summary(fit)
pp_check(fit)Check the fit by simulating replicated data, applying the same censoring bounds, and comparing the share censored per group with the observed share.
Full-uncertainty variant (multiple imputation).
Impute each sample from its own predictive distribution, analyse each
completed data set, and pool with Rubin’s rules. I-SPI stores quantiles
(conc_q_lo/med/hi), not per-sample draws, so quantified
rows must be approximated from the quantiles (for example a skew-normal
on log₁₀ matched to them), and censored rows drawn from the truncated
predictive distribution implied by the fitted model.
7. Survival-style nonparametric analysis
Left-censored concentrations become right-censored by “flipping”, t =
M − y with M larger than every y (Helsel 2012). Kaplan–Meier then
estimates the distribution of concentration without a normality
assumption, the log-rank or Peto–Prentice test compares groups, and Cox
models give covariate effects on the flipped scale. NADA2
wraps these:
library(NADA2)
left <- d$censor_type %in% c("left", "interval") # treat interval as left at its upper bound
obs <- ifelse(left, d$censor_upper, d$final_concentration)
cenfit(obs, left, d$arm) # KM medians / percentiles by arm
cen2means(obs, left, d$arm) # MLE comparison of meansTo keep the lod_to_lloq band as a genuine interval
rather than collapsing it, use a Turnbull nonparametric MLE
(icenReg::ic_np(), the interval package).
8. Threshold questions
Use the probabilities directly rather than classifying point estimates.
by_grp <- split(d$p_below_cutoff, interaction(d$arm, d$timeperiod))
expected_below <- vapply(by_grp, sum, numeric(1))
# Poisson-binomial uncertainty for the number below the cutoff, by simulation
pb <- vapply(by_grp, function(p) quantile(replicate(4000, sum(runif(length(p)) < p)),
c(.025, .975)), numeric(2))
round(rbind(n = lengths(by_grp), expected_below = expected_below, pb), 1)
#> placebo.day0 vaccine.day0 placebo.day28 vaccine.day28
#> n 60.0 60.0 60.0 60.0
#> expected_below 49.7 43.4 36.6 1.8
#> 2.5% 47.0 40.0 33.0 0.0
#> 97.5% 53.0 46.0 39.0 3.0
# Three-way classification with an explicit indeterminate group
cls <- cut(d$p_below_cutoff, c(-Inf, 0.025, 0.975, Inf),
labels = c("above", "indeterminate", "below"))
table(interaction(d$arm, d$timeperiod), cls)
#> cls
#> above indeterminate below
#> placebo.day0 6 14 40
#> vaccine.day0 11 15 34
#> placebo.day28 17 17 26
#> vaccine.day28 56 4 0Low samples routinely resolve to “below” with near certainty even
when their pcov is very large — this is where they add
information. Samples above the ULOQ, or saturated, should
usually be re-assayed at a higher dilution rather than
modelled.
9. Where precision weights fit — and a future option
curveRweights::fit_precision_weights() estimates σᵢ =
φ·sᵢ^β₁ with a saturated cell-means location and returns weights
w = 1/σ² for every sample. Two cautions follow from
sections 3 and 5:
-
Out-of-range samples. Their
se_concentrationis inflated because they are out of range, so their weights are small because their values are extreme. Weighted means lean away from the censored side (upward for low-titer groups), and those samples’ residuals distort φ and β₁. - In-range samples too. Because precision varies with the true concentration even inside the quantifiable range, inverse-variance weights are mildly informative there as well, pulling means toward the best-measured region (section 5’s table).
The planned extension handles (1): in-range rows keep their Gaussian
contribution and weight; out-of-range rows get no weight but a censoring
indicator and bounds, contributing Φ-terms with σ evaluated at the
bound. In curveRweights this means a brms::cens() term
inside the saturated location-scale model and an
as_weight_data(censoring = TRUE) option that carries
cens, y_lo, y_hi and the bound σ
through join_weights(), so a single frame feeds sections
4–6 directly. Handling (2) properly needs the latent-variable
formulation of section 5 rather than plug-in weights.
Until then, for group means and effects, prefer the unweighted censored models of sections 4 and 6; use precision weights where the goal is down-weighting genuinely noisy measurements and the precision does not track the outcome, and report a weighted-vs-unweighted sensitivity analysis.
10. Reporting checklist
- Share censored per group and side
(
table(group, censor_class)). - The method used for censored values, and why.
- Sensitivity analyses against substitution and complete case.
- Whether precision weights were used, and for which rows.
- The
decision_cutoffand probability thresholds used for classifications. - For curves with many out-of-range samples,
frac_draws_below_a/frac_draws_above_d— they show how much the legacypcovleaves out.
References
- Helsel DR (2012). Statistics for Censored Environmental Data Using Minitab and R, 2nd ed. Wiley.
- Tobin J (1958). Estimation of relationships for limited dependent variables. Econometrica 26(1):24–36.
- Lynn HS (2001). Maximum likelihood inference for left-censored HIV RNA data. Statistics in Medicine 20(1):33–45.
- Bürkner P-C (2017). brms: An R package for Bayesian multilevel models using Stan. Journal of Statistical Software 80(1):1–28.