Describes madi_results.calib_weights (one row per sample and method) and
madi_results.calib_weights_fit (one row per multiplate group and method):
column names, types, keys, which model each column applies to, and a short
plain-language description. R/calib_schema.sql holds the DDL; this function
is the same definition in a form code can check against, and a package test
keeps the two in sync.
Usage
weights_contract(table = c("all", "sample", "fit"), model = NULL)One weight set per sample
Both tables keep their original primary keys, so the sample hierarchy is the
same as calib_samples. There is one set of weights per (sample, method);
the model column records which model produced it, and re-running with a
different model replaces the set. A column that does not apply to the model
that wrote the row is NULL.
Examples
weights_contract("fit", model = "additive")[, c("column", "description")]
#> column
#> 1 multiplate_group_id
#> 2 method
#> 3 antigen
#> 4 feature
#> 5 design_cols
#> 6 scale_predictor
#> 7 beta1
#> 8 beta1_lo
#> 9 beta1_hi
#> 10 interpretation
#> 11 n_fit
#> 12 n_eff
#> 13 weight_ratio
#> 14 job_id
#> 15 created_at
#> 16 model
#> 17 weights_pkg_version
#> 18 tau
#> 19 tau_lo
#> 20 tau_hi
#> 21 kappa
#> 22 kappa_lo
#> 23 kappa_hi
#> 24 reliability
#> 25 reliability_lo
#> 26 reliability_hi
#> 27 fix_beta1
#> 28 n_censored
#> 29 identifiability
#> 30 fit_options
#> 31 rhat_max
#> 32 n_divergent
#> 33 ess_min
#> 34 ident_sd_ratio
#> 35 resid_sd
#> 36 resid_sd_ratio
#> description
#> 1 Group of plates of one antigen/feature/source fitted together.
#> 2 bayesian or frequentist.
#> 3 Antigen.
#> 4 Feature (isotype or functional readout).
#> 5 Comma-joined design columns defining the saturated cells, e.g. timeperiod,agroup.
#> 6 Precision index used: se or pcov. Additive always uses se.
#> 7 Exponent on se. Multiplicative: estimated. Additive: 1 when fix_beta1, else estimated.
#> 8 Lower 95% credible limit of beta1 (NULL when fixed).
#> 9 Upper 95% credible limit of beta1 (NULL when fixed).
#> 10 Plain-language reading of the fit (multiplicative: precision regime; additive: identifiability note).
#> 11 Observations used in the fit.
#> 12 Effective sample size of the weights.
#> 13 Largest / smallest weight.
#> 14 Compute job that wrote the row.
#> 15 Time the row was written.
#> 16 multiplicative (every pre-0.6.0 row) or additive.
#> 17 curveRweights version that produced the fit.
#> 18 SD of the true between-subject variation (log10 scale).
#> 19 Lower 95% credible limit of tau.
#> 20 Upper 95% credible limit of tau.
#> 21 Calibration factor on the reported se; 1 means se is exactly the measurement SD.
#> 22 Lower 95% credible limit of kappa.
#> 23 Upper 95% credible limit of kappa.
#> 24 Overall reliability tau2 / (tau2 + mean v_meas) over quantified rows.
#> 25 Lower 95% credible limit of overall reliability.
#> 26 Upper 95% credible limit of overall reliability.
#> 27 TRUE if beta1 was fixed at 1 rather than estimated.
#> 28 Censored observations entering the likelihood.
#> 29 Whether the signal/measurement split is set by the data or by the prior.
#> 30 JSON object of the options the additive fit actually used: use_censoring, patient_col, plate_col, fix_beta1, fix_kappa.
#> 31 Largest R-hat over the sampled parameters; above 1.05 the chains did not converge.
#> 32 Divergent transitions after warm-up; any is a sign the sampler could not explore the posterior.
#> 33 Lowest effective sample size (bulk or tail) over the sampled parameters; below about 400 the intervals are unreliable.
#> 34 Posterior SD / prior SD of the key scale parameter (additive: log kappa; multiplicative: beta1). Near 1 the prior, not the data, set it; above 1 suggests a sampling problem. NULL when that parameter is fixed.
#> 35 Robust SD of the scaled residuals (y - fitted mean) / sigma over quantified samples; about 1 when the variance model fits.
#> 36 Robust SD of the scaled residuals in the lowest-se fifth / in the highest-se fifth. About 1 when the variance model fits across the se range; above 1 the low-se samples get too much weight, below 1 the high-se samples do.